Deltech Logo

How can we help you?

deltech-hgen-75-500-group.jpg
Click to enlarge
deltech-hgen-75-500-group.jpg
deltech-hgen-lrd.jpg
deltech-hgen-300-500.jpg
deltech-hgen-75.jpg
Back to the product list

HG & HGEN Series Non-Cycling Refrigerated Air Dryers 5 to 1200 scfm

AIR & GAS TREATMENT / REFRIGERATED COMPRESSED AIR DRYERS

HG & HGEN Series Refrigerated Air Dryers Improve Productivity Simple Reliable

Features

When we streamlined our HG & HGEN Series non-cycling refrigerated compressed air dryers, our engineers focused on simplicity and reliability. Your input helped build a solution that offers the right combination of technology and simplicity to keep your air system at a dry, 38°F (+3°C) pressure dew point, from 5 through 1200 scfm. These dryers are built for durability, in a space-saving design. Sturdy sheet steel is formed and protected by an epoxy-based powdercoat finish. Plus, Deltech’s industry leading, five year warranty is now available for the HGEN Series.

Specifications

MODEL1 FLOW
RATE
SCFM2
FLOW
RATE
M3/H
REFRIGERANT VOLTAGE POWER
KW
INLET/OUTLET
CONNECTIONS
HG5-10 5 17 R 134a 115/1/60 0.2 3/8" OD
HG15 15 25 R 134a 115/1/60 0.24 3/8" OD
HG25 25 42 R 134a 115/1/60 0.41 3/4" NPT
HG35 35 59 R 134a 115/1/60 0.46 3/4" NPT
HG50 50 85 R 134a 115/1/60 0.57 3/4" NPT
HGEN75 75 127 R 134a 115/1/60 0.52 1" NPT
HGEN100 100 170 R 134a 115/1/60 0.65 1" NPT
HGEN125 125 212 R 134a 115/1/60 0.68 1" NPT
HGEN150-1 150 255 R 407c 115/1/60 0.91 1" NPT
HGEN200-4 200 340 R 407c 460/3/60 1.81 1" NPT
HGEN250-4 250 425 R 407c 460/3/60 1.92 2" NPT
HGEN300-4 300 510 R 407c 460/3/60 2.48 2" NPT
HGEN400-4 400 680 R 407c 460/3/60 3.09 2" NPT
HGEN500-4 500 850 R 407c 460/3/60 3.18 2" NPT
HGEN6003 600 1,020 R 407c 460/3/60 3.8 2" NPT
HGEN8003 800 1,360 R 407c 460/3/60 5.4 3" FLG
HGEN10003 1,000 1,700 R 407c 460/3/60 6.6 4" FLG
HGEN12003 1,200 2,040 R 407c 460/3/60 8.7 4" FLG

1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.
3 Available in water cooled
At rated conditions, pressure drop is less than 5 psig.

Dimensions

HG5-10

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG5-10 15 13 13 64


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG15

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG15 15 13 13 69


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG25

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG25 22 16 15 88


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG35

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG35 22 16 15 92


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG50

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG50 22 20 20 101


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN75

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN75 24 14 32 123


1
 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN100

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN100 24 14 32 129


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN125

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN125 24 14 32 135


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN150-1

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN150-1 24 14 35 148


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN200-4

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN200-4 30 17 36 165


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG5-10 15 13 13 64


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG15 15 13 13 69


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG25 22 16 15 88


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG35 22 16 15 92


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG50 22 20 20 101


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN75 24 14 32 123


1
 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN100 24 14 32 129


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN125 24 14 32 135


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN150-1 24 14 35 148


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN200-4 30 17 36 165


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

Performance

FLOW
MODEL
MAX
INLET AIR
PRESSURE
MIN
INLET AIR
PRESSURE
MAX
INLET AIR
TEMPERATURE
MIN
INLET AIR
TEMPERATURE
MAX
AMBIENT AIR
TEMPERATURE
MIN
AMBIENT AIR
TEMPERATURE
SCFM PSIG BARG PSIG BARG ˚F ˚C ˚F ˚C ˚F ˚C ˚F ˚C
5-10 to 50 250 17 30 2 120 49 40 4 110 43 45 7
75 to 500 232 16 43 3 120 49 45 7 110 43 37 3
600-1200 232 16 43 3 120 49 45 7 110 43 34 1

When we streamlined our HG & HGEN Series non-cycling refrigerated compressed air dryers, our engineers focused on simplicity and reliability. Your input helped build a solution that offers the right combination of technology and simplicity to keep your air system at a dry, 38°F (+3°C) pressure dew point, from 5 through 1200 scfm. These dryers are built for durability, in a space-saving design. Sturdy sheet steel is formed and protected by an epoxy-based powdercoat finish. Plus, Deltech’s industry leading, five year warranty is now available for the HGEN Series.

MODEL1 FLOW
RATE
SCFM2
FLOW
RATE
M3/H
REFRIGERANT VOLTAGE POWER
KW
INLET/OUTLET
CONNECTIONS
HG5-10 5 17 R 134a 115/1/60 0.2 3/8" OD
HG15 15 25 R 134a 115/1/60 0.24 3/8" OD
HG25 25 42 R 134a 115/1/60 0.41 3/4" NPT
HG35 35 59 R 134a 115/1/60 0.46 3/4" NPT
HG50 50 85 R 134a 115/1/60 0.57 3/4" NPT
HGEN75 75 127 R 134a 115/1/60 0.52 1" NPT
HGEN100 100 170 R 134a 115/1/60 0.65 1" NPT
HGEN125 125 212 R 134a 115/1/60 0.68 1" NPT
HGEN150-1 150 255 R 407c 115/1/60 0.91 1" NPT
HGEN200-4 200 340 R 407c 460/3/60 1.81 1" NPT
HGEN250-4 250 425 R 407c 460/3/60 1.92 2" NPT
HGEN300-4 300 510 R 407c 460/3/60 2.48 2" NPT
HGEN400-4 400 680 R 407c 460/3/60 3.09 2" NPT
HGEN500-4 500 850 R 407c 460/3/60 3.18 2" NPT
HGEN6003 600 1,020 R 407c 460/3/60 3.8 2" NPT
HGEN8003 800 1,360 R 407c 460/3/60 5.4 3" FLG
HGEN10003 1,000 1,700 R 407c 460/3/60 6.6 4" FLG
HGEN12003 1,200 2,040 R 407c 460/3/60 8.7 4" FLG

1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.
3 Available in water cooled
At rated conditions, pressure drop is less than 5 psig.

HG5-10

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG5-10 15 13 13 64


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG15

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG15 15 13 13 69


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG25

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG25 22 16 15 88


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG35

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG35 22 16 15 92


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HG50

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG50 22 20 20 101


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN75

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN75 24 14 32 123


1
 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN100

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN100 24 14 32 129


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN125

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN125 24 14 32 135


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN150-1

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN150-1 24 14 35 148


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

HGEN200-4

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN200-4 30 17 36 165


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG5-10 15 13 13 64


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG15 15 13 13 69


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG25 22 16 15 88


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG35 22 16 15 92


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HG50 22 20 20 101


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN75 24 14 32 123


1
 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN100 24 14 32 129


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN125 24 14 32 135


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN150-1 24 14 35 148


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

MODEL1 DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HGEN200-4 30 17 36 165


1 1 = For Filter Pack model, add “-FP” to standard model number. (Example: HGEN75-FP)
Dimensions, weights, and inlet/outlet connections are dryer only and do not include filtration.
Filtration package shipped loose, additional fittings may be required.
2 Rated Flow Capacity – Conditions for rating dryers are in accordance with ISO 7183 (Option A2). Compressed air at dryer inlet: 100 psig (6.7 barg) and 100˚F (38˚C); ambient air temperature: 100˚F (38˚C); operating on 60 Hz power supply.

FLOW
MODEL
MAX
INLET AIR
PRESSURE
MIN
INLET AIR
PRESSURE
MAX
INLET AIR
TEMPERATURE
MIN
INLET AIR
TEMPERATURE
MAX
AMBIENT AIR
TEMPERATURE
MIN
AMBIENT AIR
TEMPERATURE
SCFM PSIG BARG PSIG BARG ˚F ˚C ˚F ˚C ˚F ˚C ˚F ˚C
5-10 to 50 250 17 30 2 120 49 40 4 110 43 45 7
75 to 500 232 16 43 3 120 49 45 7 110 43 37 3
600-1200 232 16 43 3 120 49 45 7 110 43 34 1